CITY MULTI Y Next Generation

Introducing a new series of air conditioners with improved essential functions, advanced compressor and a streamline fan that meets energy-saving requirements. Mitsubishi Electric continues to improve air conditioning quality and provide its customers with next-generation solutions. The new structural design has a 4-face air induction design and improved core components, such as compressor and fan, significantly improving energy-saving performance.

New design

The new outdoor units of the YNW series adopt a four-sided heat exchanger mounted on the upper part of the module near the fan. The new design allows air to be taken in effectively increasing the heat exchanger’s efficiency.

New design

New YLM EP modules

Increased efficiency

New components have been added to improve energy-saving performance. Compared to the existing models, all the single modules in YNW Series have an improved EER.
EER of the 40kW model (PURY-EP350YNW-A) is higher by approximately 20%.

Advanced “Low Noise” function

The "Low noise" mode can now be selected based on five different settings: 85%, 70%, 60% and 50% (values referred to ventilation speed). Noise attenuation is directly configurable from the control board of the outdoor unit (optional PAC-SC36NA connector required). The different settings can be chosen based on the installation needs (in applications with particular noise constraints). Capacity will be reduced when operating in Low Noise mode.

Static fan pressure modifiable up to 80 Pa

The static pressure of the outdoor unit fan can be set between 0-30-60 and 80 Pa allowing the unit to be installed even in positions that require a ducting of the air expelled from the fan.
There is no drop in capacity when 80Pa External Static Pressure option is enabled.

Static fan pressure modifiable up to 80 Pa

Automatic Pump Down Function*

CITY MULTI YNW integrates with refrigerant leak detection systems.

*To detect refrigerant leak, a circuit that includes refrigerant leak detection sensor must be designed and prepared at site.

Maximum height difference increased up to 90 metres

Some models of outdoor units can operate with height differences of up to 90 metres without the use of optional kits and therefore additional costs. This simplifies and makes the design more flexible even in the tallest buildings.

Maximum height difference increased up to 90 meters

Smooth auto-shift start-up mode

The smooth auto-shift start-up mode is a new operation mode on the outdoor unit, which can now be selected in addition to the conventional COP Priority mode (the system operates maximising efficiency) and Capacity Priority mode (the system works by maximising the power supplied). This new operating mode allows the system to operate in Capacity Priority mode for the first 30 minutes and then switches to COP Priority mode. Thanks to this, the system speeds up the timing of the process. This mode is an advantage especially during the start-up of the air-conditioning system (for example, if the system is re-started early in the morning).

Smooth auto-shift start-up mode

Preheat defrost operation

The new YNW outdoor units are equipped with the Preheat defrost function which increases the air supply temperature before the system performs defrosting operations. This contributes to raising the room temperature before the start of defrost operation and prevents room occupant experiencing cold draught.

Preheat defrost operation

Emergency function (Backup)

The combined modules of CITY MULTI outdoor units guarantee an excellent level of reliability thanks to the Emergency function (Backup), which can be easily activated by the remote control of any indoor unit in case of system malfunction. The emergency function guarantees an average cooling and heating operation of 4 hours.

Emergency function (Backup)

Rotation function

The combined modules of the CITY MULTI outdoor units employ an automatic routine called "Rotation Function", to guarantee a balancing of the use of outdoor units and consequently an optimal life cycle for all system components.

Rotation function

Self-diagnosis and maintenance

Self-diagnostic information through the use of fault codes is accessible via LED status indicators on the outdoor unit circuit board. Detailed information is available by using special Maintenance Tool software developed by Mitsubishi Electric.

Self-diagnosis and maintenance

Download of operating data via USB

Unlike the previous model (YLM) in which the operating data can be downloaded via a PC equipped with appropriate software (Maintenance Tool), in the new YNW units data can be downloaded more quickly and easily with the use of a USB * data storage (USB key). It is therefore no longer necessary to bring a PC with you directly to the site where the units are installed, and this represents a saving of time, and therefore costs. Through the use of the USB key, it will be possible to download the operating data with a 5-day history. Through USB * data storage it is also possible to update the software (firmware) of the outdoor unit.
* USB data storage version 2.0 can be used

Back to Top

Models

Y Series

  • PUHY-P200YNW-A (-BS)
  • PUHY-P250YNW-A (-BS)
  • PUHY-P300YNW-A (-BS)
  • PUHY-P350YNW-A (-BS)
  • PUHY-P400YNW-A (-BS)
  • PUHY-P450YNW-A (-BS)
  • PUHY-P500YNW-A (-BS)
  • PUHY-P400YSNW-A (-BS)
  • PUHY-P450YSNW-A (-BS)
  • PUHY-P500YSNW-A (-BS)
  • PUHY-P550YSNW-A (-BS)
  • PUHY-P600YSNW-A (-BS)
  • PUHY-P650YSNW-A (-BS)
  • PUHY-P700YSNW-A (-BS)
  • PUHY-P750YSNW-A (-BS)
  • PUHY-P800YSNW-A (-BS)
  • PUHY-P850YSNW-A (-BS)
  • PUHY-P900YSNW-A (-BS)
  • PUHY-P950YSNW-A (-BS)
  • PUHY-P1000YSNW-A (-BS)
  • PUHY-P1050YSNW-A (-BS)
  • PUHY-P1100YSNW-A (-BS)
  • PUHY-P1150YSNW-A (-BS)
  • PUHY-P1200YSNW-A (-BS)
  • PUHY-P1250YSNW-A (-BS)
  • PUHY-P1300YSNW-A (-BS)
  • PUHY-P1350YSNW-A (-BS)

Y Series - High Efficiency

  • PUHY-EP200YNW-A (-BS)
  • PUHY-EP250YNW-A (-BS)
  • PUHY-EP300YNW-A (-BS)
  • PUHY-EP350YNW-A (-BS)
  • PUHY-EP400YNW-A (-BS)
  • PUHY-EP450YNW-A (-BS)
  • PUHY-EP500YNW-A (-BS)
  • PUHY-EP400YSNW-A (-BS)
  • PUHY-EP450YSNW-A (-BS)
  • PUHY-EP500YSNW-A (-BS)
  • PUHY-EP550YSNW-A (-BS)
  • PUHY-EP600YSNW-A (-BS)
  • PUHY-EP650YSNW-A (-BS)
  • PUHY-EP700YSNW-A (-BS)
  • PUHY-EP750YSNW-A (-BS)
  • PUHY-EP800YSNW-A (-BS)
  • PUHY-EP850YSNW-A (-BS)
  • PUHY-EP900YSNW-A (-BS)
  • PUHY-EP950YSNW-A (-BS)
  • PUHY-EP1000YSNW-A (-BS)
  • PUHY-EP1050YSNW-A (-BS)
  • PUHY-EP1100YSNW-A (-BS)
  • PUHY-EP1150YSNW-A (-BS)
  • PUHY-EP1200YSNW-A (-BS)
  • PUHY-EP1250YSNW-A (-BS)
  • PUHY-EP1300YSNW-A (-BS)
  • PUHY-EP1350YSNW-A (-BS)